DLN_SPI_MASTER_SET_FREQUENCY Command and Response

The DLN_SPI_MASTER_SET_FREQUENCY command is used to set the clock frequency on the SCLK line. The SCLK line synchronizes data transfer between SPI master and SPI slave devices.

DLN_SPI_MASTER_SET_FREQUENCY Command

Go to response

 typedef struct
 {
    DLN_MSG_HEADER header;
    uint8_t port;
    uint32_t frequency;
 } __PACKED_ATTR DLN_SPI_MASTER_SET_FREQUENCY_CMD;

Parameters:

header

Defines the DLN message header DLN_MSG_HEADER. The header contains several predefined fields and is used to identify and route messages. You must fill the following fields before sending the command:

Field Description
size The size of the message. Must be equal to the size of the DLN_SPI_MASTER_SET_FREQUENCY_CMD structure.
msgId Identifies the message. For the DLN_SPI_MASTER_SET_FREQUENCY command it must be set to 0x0218. You can use the DLN_MSG_ID_SPI_MASTER_SET_FREQUENCY constant.
echoCounter Can be used to link a command to a response. The response will have the same echoCounter value. This field can be any numerical value from 0 to 0xFFFF (65536).
handle A handle to the DLN-series adapter.
port
A number of the SPI master port to be configured.
frequency
SCLK line frequency value, specified in Hz. A user may specify any value within the range, supported by the DLN-series adapter. This range can be retrieved using the respective function. In case a user enters an incompatible value, it will be approximated as the closest lower frequency value, supported by the adapter.

DLN_SPI_MASTER_SET_FREQUENCY Response

Go to command

The adapter sends the DLN_SPI_MASTER_SET_FREQUENCY response after the DLN_SPI_MASTER_SET_FREQUENCY command execution. The response informs a user if the SPI clock frequency has been successfully set.

 typedef struct
 {
    DLN_MSG_HEADER header;
    DLN_RESULT result;
    uint32_t frequency;
 } __PACKED_ATTR DLN_SPI_MASTER_SET_FREQUENCY_RSP;

Parameters:

header

Defines the DLN message header DLN_MSG_HEADER. The response header contains the following fields:

Field Description
size The size of the message. It is equal to the size of the DLN_SPI_MASTER_SET_FREQUENCY_RSP structure.
msgId Contains the message id. For the DLN_SPI_MASTER_SET_FREQUENCY response it is set to 0x0218. The DLN_MSG_ID_SPI_MASTER_SET_FREQUENCY constant can be used to check the message ID.
echoCounter Links a command to a response. The echoCounter value is copied from the respective command header.
handle A handle to the DLN-series adapter. You can use the handle field to determine the adapter that have sent the response.
result

Contains the result of the command execution. For DLN_SPI_MASTER_SET_FREQUENCY command DLN-series adapter can return the following result values:

Return Code Description
DLN_RES_SUCCESS The clock frequency has been successfully set.
DLN_RES_SPI_MASTER_BUSY_TRANSFERRING The SPI module is busy transferring data and cannot currently be configured.
frequency
Contains the frequency approximated as the closest supported lower value. The value is specified in Hz.