DLN_PWM_SET_DUTY_CYCLE Command and Response
The DLN_PWM_SET_DUTY_CYCLE command is used to set a PWM duty cycle, which is the ratio of the high time to the PWM period.
DLN_PWM_SET_DUTY_CYCLE Command
typedef struct
{
DLN_MSG_HEADER header;
uint8_t port;
uint8_t channel;
uint16_t bsDutyCycle;
} __PACKED_ATTR DLN_PWM_SET_DUTY_CYCLE_CMD;
Parameters:
- header
-
Defines the DLN message header DLN_MSG_HEADER. The header contains several predefined fields and is used to identify and route messages. You must fill the following fields before sending the command:
Field Description size The size of the message. Must be equal to the size of the DLN_PWM_SET_DUTY_CYCLE_CMD structure. msgId Identifies the message. For the DLN_PWM_SET_DUTY_CYCLE command it must be set to 0x070A. You can use the DLN_MSG_ID_PWM_SET_DUTY_CYCLE constant. echoCounter Can be used to link a command to a response. The response will have the same echoCounter value. This field can be any numerical value from 0 to 0xFFFF (65536). handle A handle to the DLN-series adapter. - port
- A number of the PWM port to set the duty cycle for.
- channel
- A number of the PWM channel to set the duty cycle for.
- bsDutyCycle
- The duty cycle to be set. This is a basis point parameter.
DLN_PWM_SET_DUTY_CYCLE Response
The adapter sends the DLN_PWM_SET_DUTY_CYCLE response after the DLN_PWM_SET_DUTY_CYCLE command execution. The result field informs a user if the new duty cycle has been successfully set. Also, the response contains actual duty cycle value, in case the one specified by a user is not supported by the DLN-series adapter.
typedef struct
{
DLN_MSG_HEADER header;
DLN_RESULT result;
uint16_t bsDutyCycle;
} __PACKED_ATTR DLN_PWM_SET_DUTY_CYCLE_RSP;
Parameters:
- header
-
Defines the DLN message header DLN_MSG_HEADER. The response header contains the following fields:
Field Description size The size of the message. It is equal to the size of the DLN_PWM_SET_DUTY_CYCLE_RSP structure. msgId Contains the message id. For the DLN_PWM_SET_DUTY_CYCLE response it is set to 0x070A. The DLN_MSG_ID_PWM_SET_DUTY_CYCLE constant can be used to check the message ID. echoCounter Links a command to a response. The echoCounter value is copied from the respective command header. handle A handle to the DLN-series adapter. You can use the handle field to determine the adapter that have sent the response. - result
-
Contains the result of the command execution. For DLN_PWM_SET_DUTY_CYCLE command DLN-series adapter can return the following result values:
Return Code Description DLN_RES_SUCCESS The new PWM duty cycle has been successfully set. - bsDutyCycle
- Actually set duty cycle. This is a basis point parameter.