DLN_GPIO_SET_DEBOUNCE Command and Response
The DLN_GPIO_SET_DEBOUNCE command is used to specify the minimum duration of the pulse to be registered (the Debounce interval).
DLN_GPIO_SET_DEBOUNCE Command
Syntax
- C/C++
-
typedef struct { DLN_MSG_HEADER header; uint32_t duration; } DLN_GPIO_SET_DEBOUNCE_CMD;
Parameters:
- header
-
Defines the DLN message header DLN_MSG_HEADER. The header contains several predefined fields and is used to identify and route messages. You must fill the following fields before sending the command:
Field Description size The size of the message. Must be equal to the size of the DLN_GPIO_SET_DEBOUNCE_CMD structure. msgId Identifies the message. For the DLN_GPIO_SET_DEBOUNCE command it must be set to 0x0104. You can use the DLN_MSG_ID_GPIO_SET_DEBOUNCE constant. echoCounter Can be used to link a command to a response. The response will have the same echoCounter value. This field can be any numerical value from 0 to 0xFFFF (65536). handle A handle to the DLN-series adapter. - duration
- Minimum duration of the pulse to be registered. The duration is specified in μs from 1μs up to 4,294,967,295μs (~1h 10m). This value will be approximated as the closest debounce duration supported by the adapter. See Debounce Filter for details.
DLN_GPIO_SET_DEBOUNCE Response
The adapter sends the DLN_GPIO_SET_DEBOUNCE response after the DLN_GPIO_SET_DEBOUNCE command execution. The response will contain the minimum pulse duration approximated as the closest to user-defined value.
Syntax
- C/C++
-
typedef struct { DLN_MSG_HEADER header; uint8_t result; uint32_t duration; } DLN_GPIO_SET_DEBOUNCE_RSP;
Parameters:
- header
-
Defines the DLN message header DLN_MSG_HEADER. The response header contains the following fields:
Field Description size The size of the message. It is equal to the size of the DLN_GPIO_SET_DEBOUNCE_RSP structure. msgId Contains the message id. For the DLN_GPIO_SET_DEBOUNCE response it is set to 0x0104. The DLN_MSG_ID_GPIO_SET_DEBOUNCE constant can be used to check the message ID. echoCounter Links a command to a response. The echoCounter value is copied from the respective command header. handle A handle to the DLN-series adapter. You can use the handle field to determine the adapter that have sent the response. - result
-
Contains the result of the command execution. For DLN_GPIO_SET_DEBOUNCE command DLN-series adapter can return the following result values:
Return Code Description DLN_RES_SUCCESS Debounce interval has been successfully set. DLN_RES_COMMAND_NOT_SUPPORTEDD Debounce filtering is not supported in the adapter. - duration
- Contains minimum debounce interval approximated as the closest to user-defined value. The duration is specified in μs.
2006-2012